The prototype for this valve is E1468.
Saturation occurs with an anode voltage not greater than 50V. At a filament voltage of 7V the life of the valve is reduced to 100 hours. The value of the saturated anode current is normally regulated by variation of filament voltage.
|
![]() |
||||||||||||||||||||||||||||||||
Views of the internal structure of the valve. The filament is a single hairpin supported in the centre by a spring. The anode is supported at each side by metal plates which also support the getter carrier at the top of the envelope. |
|||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||